G
Astro function – Europe Special functions
- 59 -
DIP 2 DIP 3 DIP 4 DIP 5 Area
ON OFF OFF OFF Scandinavia
ON OFF OFF ON Great Britain
ON OFF ON OFF Northern France, Benelux
ON OFF ON ON Germany
ON ON OFF OFF Southern France
ON ON OFF ON Switzerland, Austria, Northern Italy
ON ON ON OFF Spain
ON ON ON ON Southern Italy, Sicily, Corsica, Sardinia
G
Special functions Reverse function
After the roller shutter has moved down automatically at the pro-
grammed time, the reverse function causes the roller shutter to shortly
move up shortly for airing purposes or to let pets go outside.
The reverse time can be set with DIP switches 7 and 8 and will only
be executed at the programmed day, week and sunrise/sunset times
during automatic operation. The reverse function can also be exe-
cuted by pushing the down button during automatic operation.
Important: The reverse function is only initiated 2 minutes after the
down pulse has been transmitted.
Setting reverse time:
The display will indicate the
set reverse time with the
symbol (
O
).
This symbol flashes on the
display during execution of
the reverse time.
- 60 -
DIP 7 DIP 8 Reverse time
OFF OFF none
OFF ON 2 seconds
ON OFF 4 seconds
ON ON 10 seconds